BWQVM - GACOFLEX A-57 SERIES
- MSDS: BWQVM
- Manufacturer: GACO WESTERN INC
- Product Name: GACOFLEX A-57 SERIES
- National Stock Number: 8010-00N057537
Product Identification
Product ID:GACOFLEX A-57 SERIES
MSDS Date:01/01/1989
FSC:8010
NIIN:00N057537
MSDS Number: BWQVM
Responsible Party
SEATTLE, WA 98188-4636
US
Emergency Phone: 206-575-0450
Info Phone: 206-575-0450
Cage: 09463
Contractor
Telephone: 206-575-0450
Cage: 09463
Ingredients
DIPROPYLENE GLYCOL, MONOMETHYL ETHER; (DIPROPYLENE GLYCOL
CAS: 34590-94-8
RTECS: JM1575000
Fraction By Weight: 1.9%
OSHA PEL 100 PPM, S
ACGIH TLV: 100 PPM;150PPMSTEL,S
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:NONE CURRENTLY KNOWN.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYE: FLUSH WITH WATER FOR AT LEAST 15 MINUTES. SKIN: WASH
WITH SOAP AND WATER, REMOVE CONTAMINATED CLOTHING. INGESTION: CALL
PHYSICIAN IMMEDIATELY. INHALATION: REMOVE FROM EXPOSURE. SUPPORT
BREATHING (GIVE ARTIFICIAL RESPIRATION/OXYGEN) .
Fire Fighting
Extinguishing Media:FOAM, ALCOHOL FOAM, CARBON DIOXIDE, DRY CHEMICAL
AND WATER FOG.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . COOL CONTAINERS WITH WATER FOG TO PREVENT
RUPTURE.
Unusual Fire/Explosion Hazard:CLOSED CONTAINERS MAY RUPTURE WHEN
EXPOSED TO EXTREME HEAT.
Accidental Release
Spill Release Procedures:SPILLS SHOULD BE COLLECTED FOR DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE IN COOL DRY PLACE AWAY FROM
DIRECT SUNLIGHT.
Other Precautions:AVAILABLE DATA SHOWS THAT NONE OF INGREDIENTS ARE
CARCINOGENIC, TERATOGENIC OR MUTAGENIC BUT MATERIAL MAY BE HARMFUL
OR FATAL IF SWALLOWED. MAY CAUSE SKIN OR EYE IRRITATION.
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR REQUIRED IN
CONFINED OR POORLY VENTILATED AREAS.
Ventilation:GENERAL ROOM VENTILATION IS SATISFACTORY.
Protective Gloves:PLASTIC OR RUBBER GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGG .
Other Protective Equipment:ANSI APPRVD EYE WASH, FACE SHIELD AND SAFETY
SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
Chemical Properties
Boiling Pt:B.P. Text:>200F,>93C
Vapor Pres:SEE ING
Vapor Density:LTR/AIR
Spec Gravity:1.426
Evaporation Rate & Reference:SLOWER (ETHER=1)
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:48
Stability
Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:TEMPERATURE EXTREMES.
Hazardous Decomposition Products:WHEN WATER EVAPORATES, SOLIDS CAN BURN
AND PRODUCE CARBON MONOXIDE AND/OR CARBON DIOXIDE.
Disposal
Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH LOCAL, STATE, AND
FEDERAL REGULATIONS. INCINERATE IN APPROVED FACILITY. DO NOT
INCINERATE CLOSED CONTAINERS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.